270 ONBOARD REFERENCE LINKS!
They're for inspectors: the following reference material links are permanently installed onboard my Hive Residential template, giving you immediate access to a huge amount of accurate information during the inspection.
They're for clients: these links can be pasted into comments to give clients more detailed information about a condition.
All links live under a single title in each section so they don't clutter the template.
ROOF
COMMON ROOF ELEMENTS
- Roof Coverings: IRC Links Links to all the roof-covering materials in the International Residential Code
- InterNACHI Roof Standards of Practice: onboard notes
- Inspecting the Roof Structure Exterior
- Steep-slope Roof Drainage
- Low-slope Roof Drainage
- Roof vent Identification See what these vents serve with a glance at the roof!
- Combustion vent Termination Heights This link is to UP Codes. Select your state and look for IFGC 503.6
STEEP-SLOPE ROOFING
ASPHALT SHINGLE REFERENCE LIBRARY
One onboard link gives you access to a page with the following links::
- Asphalt Shingle Inspection Concerns;
- 2021 IRC R905.2 Asphalt Shingles;
- Mastering Roof Inspections ; (Asphalt Shingles (#55-#109)
- Asphalt Shingle Inspection Field Guide,, $18.99, by Kenton Shepard
- Inspecting Shingle Bonding;
- Craze-cracking;
- Identifying Wind Damage;
- Batch Problems;
- Blisters VS Hail Damage;
- Biological Growth;
- Uniform Granule Loss;
- Racking of Shingles (GAF Technical Advisory Bulletin)
- Buckling of Shingles
- About Shingle Warranties
- Factors Affecting Shingle Aging
- White/Brown Stains below Roof Vents;
- The History of Asphalt Shingles (CASMA)
- Asphalt Shingle Sealant Strips (Donan Engineering)
- Impact Resistance of Asphalt Shingles (Insurance Institute for Business and Home Safety)
- 66 GAF Technical Bulletins
- Telescoping Ladder Maintenan
- FM Global: Roof Inspection Resources
- Asphalt Roofing Manufacturer's Association
- InterNACHI Asphalt Shingle Inspection online video course (3.25 hrs, InterNACHI members only)
- Building Codes At this page, for general IRC information, choose ICC, for jurisdictional (state and city) building codes, choose UP Codes. go to Chapter 9, Roof Assemblies.
Other Steep-slope Roof-covering Materials
- Concrete Tile Reference Library
- Tile Roof Inspection Field Guide PDF $18.99, by Kenton Shepard
- Clay Tile Reference Library
- Metal Roof Inspection Concerns
- Stone Slate Reference Library
- Slate Inspection Field Guide PDF $18.99 by Kenton Shepard
- Composite Slate Reference Library
- Roll Roofing Reference Library
- Wood Shake Inspection Concerns;
- Wood Shake & Shingle Inspection Field Guide PDF $18.99 by Kenton Shepard
- Wood Shingle Inspection Concerns;
- Cedar Shake and Shingle Bureau:
- Wood Shake & Shingle Inspection Field Guide PDF
- Fiber-cement Reference Library
LOW-SLOPE ROOFING
- Built-up Roof Reference Library
- Identifying the number of Built-up Plies
- EPDM Reference Library
- Modified Bitumen Reference Library
- TPO Reference Library
-
View photos of TPO flashing
-
-
PVC Reference Library
-
View photos of PVC flashing
-
- Sprayed Polyurethane Foam Reference
EXTERIOR
- InterNACHI Exterior Standards of Practice: onboard notes
- Underground Fuel Oil Tank Reference
- Driveways/walkways: Visual Inspection of Concrete: a comprehensive article on inspecting concrete.
- Stair Checklist
- Using UPCodes, you can look up stairway code provisions for your state here. Stair provisions are located in Means of Egress, chapter 3.
- Clearances: Combustion Exhaust vents VS Door and Window Openings and Fresh Air Intakes
EXTERIOR WALL COVERINGS
- Brick
- Inspecting Brick Walls
- Brick Cladding VS. Solid Masonry Walls
- Types of Brick
- Structural Brick
- Brick Cladding VS. Solid Masonry Walls
- Inspecting Brick Walls
- Structural Brick Wall Failure
- Inspecting Composite Siding (LP Smartside)
- Inspectors without special training should disclaim inspection of EIFS, DEFS, and hard coat stucco. Training is offered by both InterNACHI and the Exterior Design Institute.
- Inspecting Fiber-cement Siding
- Vinyl Siding
- Inspecting Vinyl Siding
- Vinyl Siding Installation Manual (Vinyl Siding Institute)
- Inspecting Wood Siding
- Inspecting Wood Shingle Siding
- Inspecting Manufactured Stone veneer
DECKS
- Deck Inspection Concerns
- Deck Ledger Attachments: Best Practice (by siding type)
- Minimum deck clearance for Emergency Escape and Rescue Openings.
GARAGE
- Garage Inspection Concerns
- Inspecting the Overhead Garage Door
- Inspecting Automatic Openers
- IRC stair provisions (by state)
- Fire Separation Walls/Ceiling
- For fire wall/ceiling separation provisions, go here
- For local codes, go here, choose your jurisdiction, and scroll to the relevant provisions.
- Garage Electrical: onboard notes
- Inspecting Roof Trusses
- Inspecting Conventional Roof Framing
GENERAL STRUCTURE
GENERAL STRUCTURE REFERENCE LIBRARY
One onboard link gives you access to a page with the following links:
- Notching and Boring Guides for sawn and Engineered Lumber, Studs, Joists, Beams, and Glulams.
- Adjustable Steel Posts
- Wood Deterioration and Decay
- Simpson Strong Tie Wood Connectors catalogue ( you may need to update this link occasionally)
- Inspecting Floor Structures
- About Shear Walls
- Expansive Soil
- Crack Analysis
- Post-fire Assessment of Framing
- Building Science Corporation: An important source of free information on building science. Select "Articles and Papers".
Other Structure Links
- InterNACHI Structure Standards of Practice: onboard notes
- Foundation Wall Reference Library
- Inspecting Adjustable Steel Posts
- View the standards for wood foundation construction.
- Efflorescence in Foundation Walls
- Reinforced Concrete Damage Ratings
- Concrete Foundation Walls
- Efflorescence in Concrete Foundation Walls
- Crack Analysis
- Reinforced Concrete Damage Ratings
- Framed Floor Structure
- Inspecting Floor Structures
- Notching and Boring Guides for sawn and engineered lumber, studs, joists, beams, and Glulams.
- Inspecting Adjustable Steel Posts
- Perimeter Bearing Requirements: onboard notes
- Basement
- Inspecting Adjustable Steel Post
- Emergency Escape and Rescue Openings Choose your state and look in IRC Chapter 3
- Crawlspace: onboard notes
ATTIC
- Attic Access: onboard notes
- Attic Thermal Envelope
- Attic Thermal Insulation
- Attic Utility Inspection Concerns
- Potential Hazards of Radiant Barrier Sheathing:
- Radiant barrier sheathing Study 1
- Radiant Barrier sheathing study 2
- Attic Pests and Inspector Safety
- Personal Protective Equipment
- If You Encounter Bats!
- Attic Chimney Inspection Concerns: onboard notes
ROOF STRUCTURE
- Roof Structure Ventilation
- Inspecting Conventional Roof Framing
- Inspecting Truss Roof Framing
- Inspecting Roof Sheathing
- Inspecting Roof Framing Fasteners and Connectors
- Post-fire Assessment of Roof Framing
GENERAL INTERIOR
- InterNACHI Interior Standards of Practice
- Wood Flooring
- Wood floor inspection
- Problems, Causes and Cures: manual by the National Hardwood Floor Association
- 2021 IRC Required Lighting Locations
- Inspecting Doors
- Inspecting Windows
- Inspection of Window Interiors; Links to a page listing common concerns including safety glass requirements.
- Thermal Pane Window Failure (an excellent explanation from Pella Windows)
- Stairways
- Stairway Inspection Concerns
- Using UPCodes, you can look up stairway provisions for your jurisdiction here. Stair provisions are located in Means of Egress, chapter 3.
- Inspecting Dryer Vents
- Fire Related:
- Use this link to look up the fire safety codes for the areas in which you inspect.
- For fire separation provisions, go here, Select your jurisdiction, and scroll to Fire Separation R302
- Emergency Escape and Rescue Openings by jurisdiction
- Emergency Escape and Rescue Openings (web page with diagrams)
- Environmental Hazards
- About Mold
- About Radon
- Radon Certification
KITCHEN
- Inspecting Kitchen Appliances
- Kitchen range
- Inspecting Kitchen Ranges
- Inspecting Gas and Electric Ranges InterNACHI article
ELECTRICAL
- InterNACHI Electrical Standards of Practice: onboard notes
- Electrical Service
- Inspecting the Service Drop
- Service Clearances can Vary!
- Links to the major US electrical utilities
- Service Panel
- Service Panel Inspection Concerns
- Double-tapped breakers Identification and fix
- Backfed Breakers
- Shunt Trip Breakers
- Panel Labels
- Conductor Types
- Bonding Bushings
- Federal Pacific Stab-Lok Hazards
- Zinsco Panel Hazards
- Square D QO model RECALL (details provided)
- Neutral Conductor Concerns
- Types of Panelboards
- Service Panel Grounding and Bonding
- Service electrical Grounding
- Service electrical Bonding
- Sub-panel Inspection Concerns
- Sub-panel Grounding and Bonding
- Floating Neutral Bus Bar
- Outbuilding Grounding Requirements
- Branch Circuit and Device Reference
- Branch Wiring Inspection Concerns;
- GFCI Location History (when and where it was required);
- AFCI and GFCI Requirements by State;
- Testing GFCI Receptacles
- Outbuilding Grounding Requirements
- Bootleg Grounds
- Conductor Types
PLUMBING
- InterNACHI Plumbing Inspection Standards of Practice: onboard notes
- Approved water distribution Pipe Material and Mimimum Support Intervals
- Water Heater
- Water Heater Inspection Concerns
- Find the date of manufacture using the serial number
- Temperature/Pressure Relief (TPR) Discharge Pipe Regulations
- Water Heater Backdrafting: Causes and Recognition
- Why Water Tanks Leak
- Discolored Hot Water
- Rumbling, Cracking, Popping Sounds
- Electric Water Heater
- About Water Temperature
- Gas System: onboard graphics
- 2021 International Fuel Gas Code
- 2020 LP Gas Code
- Approved gas pipe distribution materials and maximum support intervals
- Gas vent termination minimum heights above the roof
- Inspecting CSST
- Toilet: onboard notes
- Bathtub: onboard notes
- Shower: onboard notes
- About Plumbing Cleanouts
- Sewer/waste pipe maximum support intervals
- About Sewer Scope
- Sump Pump Inspection
- Inspecting Sewage Ejectors
- Water Wells
- Inspecting Private Water Wells
- InterNACHI Water Well Inspection Course
- Septic Systems
- About inspecting Septic Systems
- National Association of Wastewater Transporters (NAWT) training
HVAC
- InterNACHI HVAC Inspection Standards of Practice: onboard notes
- Furnace Reference Library
- 2021 International Fuel Gas Code ( IFGC)
- Gas Furnace Inspection Concerns;
- Gas Furnace Operation;
- Find the date of manufacture using the serial number.
- Combustion Air Requirements;
- Furnace Efficiency;
- Venting High-Efficiency Combustion Appliances Into Masonry Chimneys;
- By-Passing Unfamiliar Thermostats;
- Carbon Monoxide;
- Identifying A Cracked Heat Exchanger;
- Inspecting Humidifiers
- Cooling Reference Library
- Inspecting Split AC Systems;
- Acceptable refrigerant line temperatures.
- Heat Pump Inspection Concerns;
- Inspecting Mini-splits.
- HVAC Mfg. Date Codes (find the date of manufacture using the serial number)
- Temperature Stratification in Multi-story Homes
- AC Warranty
- Inspecting Split AC Systems;
- Inspecting HVAC Ducts (article)
- Return Air Information: onboard notes
- Boiler Reference Library
- Inspecting Gas-fired Boilers InterNACHI article
- Find Date of manufacture here using the serial number
- TPR Discharge pipe Regulations
- Gas Vent Termination Heights
- Fireplace: : onboard notes
- National Fireplace Institute
- Heat Pump Inspection
- Inspecting Mini-splits
ENVIRONMENTAL HAZARDS
- Mold Reference Library
- About Mold
- American Academy of Allergy, Asthma, and Immunology on mold
- EPA on Mold
- Radon REference Library
- About Radon
- Becoming certified to perform radon measurement in real estate transactions
- U.S. EPA page on radon
- Cleveland Clinic on health risks from radon
- FEMA Earthquake Hazard Maps
- Wildfire
- Wildfire Risk Map
- INL Wildfire Survey Template
- Wildlife Hazard Information: onboard notes
- InterNACHI's Lead-Safe Work Practices for Home Inspectors Course
POOL and SPA
- InterNACHI Standards of Practice for Inspecting Pools and Spas: onboard notes
- Barrier Sstems
- 2024 International Pool and Spa Code (Section 305 Barrier requirements)
- 2024 Pool and Spa Code (by jurisdiction).
- Pool Decks
- 2024 International Pool and Spa Code (Section 306 Deck requirements)
- 2024 Pool and Spa Code (by jurisdiction).
- Coping
- 2024 International Pool and Spa Code (Section 306 Deck requirements)
- 2024 Pool and Spa Code (by jurisdiction).
- Inspecting Pool Vessels
- Inspecting Residential Pool Drains
- Virginia Graeme Pool and Spa Safety Act
- Pool/Spa Electrical Systems
- Inspecting Pool Electrical Systems
- 2024 International Swimming Pool and Spa code (Section 322. Lighting)
- 2024 Pool and Spa Code (by jurisdiction).
- 2024 International Residential Code (IRC) (Section E4203 Equipment Location and Clearances)
- 2023 National Electric Code (NEC) Swimming (Pool Grounding and Bonding)
- Inspecting Swimming Pool Pumps
- Inspecting Swimming Pool Control Systems
- Inspecting Automatic Sanitation
- Inspecting Pool Heating Systems
- Inspecting Pool Plumbing Systems
- Inspecting Pool Filters
- Inspecting Hot Tubs
LOG HOME
- Log Home Reference
- Log Home Inspection Concerns
- 2022 ICC 400 Standard on the Design and Construction of Log Structures
- InterNACHI's Log Home Inspection course (I wrote it)
- International Log Builder's Association
- Log Home Inspection Checklist only $29.99!
- Find advice and products here:
- Sashco
- Permachink
- Inspecting Log Home Roofs
- Inspecting Log Walls
- Wall log Settling and Shrinkage
- Inspecting Corner Notches
- Inspecting Log Extensions
- Log Home Chinking
- Inspecting Chinking
- Common Chinking Problems
- Inspecting Log Floor Structures
- Inspecting Log Finish Coatings
- Wood Decay
- Inspecting for Wood Decay
- About Wood Decay
BUILDING CODES
UpCodes has most state/jurisdictional-specific building codes
ICC Codes has the basic ICC codes without jurisdictional adjustments
REPORT WRITING
- Report Compilation Time and Length
- The 3 Functions of a Narrative;
- Urgency in Narratives
- Citing Code Provisions in the Report
- Including Photos and Videos
- How will AI Affect Home Inspection Businesses?
- Developing a Recommendation Lexicon
- Report Writing Guide, $29.95 by Kenton Shepard